Once received the replacement electronic board, please follow the below assembly instructions.
ATTENTION: to avoid electronic malfunctions, when the home trainer is not in use PLEASE REMOVE THE POWER CABLE DIRECTLY FROM THE HOME TRAINER AND ONLY AFTER FROM THE WALL SOCKET.
Click on the name of your trainer for the correct procedure:
REALTOUR / QUBO DIGITAL / QUBO DIGITAL SMART B+ / INTERA / EVO / NOVO SMART
DIRETO / DIRETO X / DIRETO XR
DRIVO / DRIVO II
ZUMO
SUITO
NERO
TUO
RAMPA
REAL TURBOMUIN / REAL TURBOMUIN B+
AVANTI
Please follow the video instructions:
Click on the following link to view the French version of the video: https://youtu.be/0jtXkzjnmBY
Remember to run the calibration procedure after replacing the electronic board:
Calibration interactive hometrainers with myE-Training app/software
JUSTO - JUSTO 2
Please follow the video instructions:
Click on the following link to view the French version of the video: https://youtu.be/0jtXkzjnmBY
Remember to run the calibration procedure after replacing the electronic board:
Calibration interactive hometrainers with myE-Training app/software
REALTOUR / QUBO DIGITAL / QUBO DIGITAL SMART B+ / INTERA / EVO / NOVO SMART
Please follow the video instructions:
Click on the following link to view the French version of the video: https://youtu.be/ye7nJ9BfrPk
DIRETO / DIRETO X / DIRETO XR
Please follow the video instructions:
Click on the following link to view the French version of the video: https://youtu.be/Xieoc6opKMY
Remember to run the calibration procedure after replacing the electronic board:
Calibration interactive hometrainers with myE-Training app/software
If you receive a new electronic board with the ground cable as shown in the picture below (black cable):
Follow the procedure described in the video but before installing the board remove the screw highlighted below with a Phillips-head screwdriver PH2.
Insert on the screw the metal ring positioned at the end of the cable and then refix it.
DRIVO / DRIVO II
Follow one of these 3 procedures depending on the electronic board that needs to be replaced:
1. If the following is the electronic board to replace:
In this case, you'll receive a new electronic board and two adapter cables that will substitute both boards
Proceed as follows:
Click on the following link to view the French version of the video: https://youtu.be/y6WVPPXayww
2. If this is the electronic board to be replaced:
Please follow the instructions at this link:
Click on the following link to view the French version of the video: https://youtu.be/54W0UlGwn84
In both cases, after the replacement, please proceed with the home trainer calibration:
Calibration interactive hometrainers with myE-Training app/software
3. If you received the power electronic board:
Please follow the on-screen instruction at this link:
In this case, after replacing it, calibration is not required
ZUMO
Please follow the instructions in the video below:
Click on the following link to view the French version of the video: https://youtu.be/bl442JkVdT4
Remember to run the calibration procedure after replacing the electronic board:
Calibration interactive hometrainers with myE-Training app/software
SUITO
Please follow the instructions in the video below:
Click on the following link to view the French version of the video: https://youtu.be/-30QSCTHWSo
Remember to run the calibration procedure after replacing the electronic board:
Calibration interactive hometrainers with myE-Training app/software
If you receive a new electronic board with the ground cable as shown in the picture below
Integrate the procedure described in the video above with the following step before closing the panel of the trainer to assemble the ground cable:
- bend the cable slightly to give it a shape favorable to installation
- place the highlighted screw in the shell and on the inside part insert the metal ring positioned at the end of the cable:
At last, fix and tighten the screw of the panel and then all the others to completely assemble the cover.
NERO
Please follow the instructions in the video below:
Click on the following link to view the French version of the video: https://youtu.be/1Fmny_gSJPQ
Remember to run the calibration procedure after replacing the electronic board:
Calibration interactive hometrainers with myE-Training app/software
TUO
Please follow the instructions in the video below:
Click on the following link to view the French version of the video: https://youtu.be/WlsC4uLUwwY
Remember to run the calibration procedure after replacing the electronic board:
Calibration interactive hometrainers with myE-Training app/software
RAMPA
Please follow these instructions:
-
Unscrew the 7 screws that hold the 2 plastic parts together and remove the external shell:
-
Remove the washer below:
-
Unscrew the 2 self-threading screws that hold the electronic board to the shell, remove the old electronic board and place the new one:
ATTENTION: the ferrite must be positioned like showed on image below:
-
Assembly the external shell by adding the washer indicated on point 2, screw completely the 7 screws on the shell (ref. images 1-2)
REAL TURBOMUIN / REAL TURBOMUIN B+
1) It is absolutely necessary to discharge the accumulated static electricity during the following operations to avoid damaging the electronic board drivers
- Use a proper antistatic wrist strap, available in electronics store.
- Alternatively, we can discharge the static electricity on our body by touching a radiator, a faucet or any grounded metallic appliance (this can be done multiple times during the following operations).
2) Remove the three screws that hold the plastic cover in place on the aluminium shell.
3) Make sure you discharged the static electricity accumulated on your body (see point 1). Use a screwdriver to remove the three screws that hold the electronic board on the aluminium shell.
4) Gently remove the switch, the stepping motor and speed sensor connectors using a small screwdriver (without pulling the wires) to avoid damaging the board components and the cables.
5) Remove the screw that connects the ground cable of the electronic board to the aluminium shell.
6) Replace the electronic board. Make sure you discharged the static electricity accumulated on your body (see point 1). While handling the electronic board try to hold it by its edges without touching the electronic components on its upper and lower parts. Attach the ground cable (yellow and green) to the aluminum shell.
7) Gently insert the three connectors (depicted as follows) in the same positions they had been previously removed from.
8) Make sure you discharged the static electricity accumulated on your body (see point 1). Attach the electronic board to the aluminium shell by tightening the three screws you previously removed.
9) Test motor movement by connecting the power supply. The positioning shaft will touch the switch at its minimum level, then will set in the default position (about 2 cm from the switch, depicted as follows).
10) Once you made sure that the braking system moves properly, close the white cover by tightening the three screws, make sure you don't pinch the three cables connected to the board.
11) Once again test the braking unit by inserting again the power supply. The home trainer should now make a buzzing noise that lasts about 10 seconds, which means that the board replacement operations has been properly conducted